Optimum Performance - Without the Odor
Introducing TruLo® Lo Odor asphalt. It takes most of the annoying odor out of every hot asphalt job.
The Sweet Smell of Innovation.
Owens Corning uses a patent-pending technology specifically formulated to neutralize asphalt odor without impacting asphalt performance. Testing shows:
- A 50% odor reduction in TruLo® Lo Odor asphalt as compared to Trumbull standard asphalt
- When compared to leading competitive low-odor asphalts and additives, TruLo® Lo Odor asphalt was 45% more effective at reducing odor-causing compounds
Now Odor Doesn't Have to Dictate Scheduling
Many customers are understandably bothered by the odor of typical built-up roofing. TruLo® Lo Odor asphalt:
- Helps you avoid costly night and weekend work scheduling due to odor issues
- Was developed to allow BURA to be used for even the most odorsensitive sites, such as schools, restaurants and hospitals
- Significantly reduces odor complaints
Keep Your Kettle Routine
TruLo® Lo Odor asphalt follows the same kettle processing as standard asphalt—there is no messy, dangerous mixing of additives.
- Works effectively to control odor both on the roof and at the kettle
- Available at Trumbull distributor locations nationwide
- Call 1-800-GET-PINK™ for the distributor nearest you
TruLo® Lo Odor Asphalt Brochure
|
Typical Physical Characteristics for TruLo® Lo Odor Asphalt
| |
Type I |
Type II |
Type III |
Type IV |
|
| Softening Point (ºF) |
140-150 |
165-175 |
195-205 |
210-225 |
|
|
| Flash Point (ºF) |
525 |
525 |
525 |
525 |
|
|
| Penetration, Units, dmm: |
|
| @77ºF |
20-35 |
20-30 |
17-24 |
15-22 |
|
|
| Ductility @77ºF, cm |
13 |
4.0 |
3.0 |
2.0 |
|
|
| Solubility in Trichoroethylene % |
99.8 |
99.8 |
99.8 |
99.8 |
|
|
| Typical Application Temperature |
|
|
|
|
|
| For Hand Mopping |
|
|
|
|
|
| EVT @125 CPS +/- 25ºF |
350 |
375 |
430 |
450 |
|
| For Machine Spreader |
|
|
|
|
|
| EVT @ 75 CPS +/- 25ºF |
370 |
395 |
455 |
475 |
|
| Features |
Benefits |
| All products meet ASTM D312 |
Each shipment meets or exceeds the physical requirements of the specified roofing grade asphalt |
|
| Consistent high flash material |
Proper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum |
|
| Testing in each plant and at Summit, IL laboratory |
All Owens Corning Trumbull products are assured to meet ASTM requirements |
|
| 19 producing plants |
Convenient, accessible availability from coast to coast |
|
| EVT shown on each carton and bill of lading for bulk shipments |
Assures proper adhesion, waterproofing and application rate |
|
| Printed cartons |
Clearly identifies manufacturers, type, flash point, EVT, production location and production date |
|
Physical Requirements - ASTM D312-00
| |
Type I |
Type II |
Type III |
Type IV |
Test Methods |
| |
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
| Softening Point (ºF) |
135 |
151 |
158 |
176 |
185 |
205 |
210 |
225 |
ASTM D36 |
|
| Flash Point (ºF) |
500 |
|
500 |
|
500 |
|
500 |
|
ASTM D92 |
|
| Penetration, Units, dmm: |
| @32ºF |
3 |
|
6 |
|
6 |
|
6 |
|
ASTM D5 |
| @77ºF |
18 |
60 |
18 |
40 |
15 |
35 |
12 |
25 |
|
| @115ºF |
90 |
180 |
|
100 |
|
90 |
|
75 |
|
|
| Ductility @77ºF, cm |
10.0 |
|
3.0 |
|
2.5 |
|
1.5 |
|
ASTM D113 |
|
| Solubility in Trichoroethylene % |
99 |
|
99 |
|
99 |
|
99 |
|
ASTM D2042 |
|
| Asphalts shall be homogenous and free of water and shall conform to these physical properties |
|
| Plant Specific EVTs
|
|
|